Some behaviour is normal
A heat pump in heating mode absorbs heat from the outdoor air. On cold, damp mornings the outdoor coil drops below freezing, frost forms, and the unit periodically switches into defrost to melt it. During defrost the indoor fan usually stops and you may see steam or water from the outdoor unit. That cycle is normal and should clear within a few minutes.
When it is a fault
Persistent ice that never clears, a unit that spends most of its time defrosting, or air that stays cool after ten minutes of running all point to a fault. The usual causes are a dirty outdoor coil, a failed defrost sensor, a reversing valve problem, low refrigerant or a control setting that is fighting the unit.
- Outdoor coil blocked by salt, dust or vegetation.
- Defrost sensor or board not initiating a defrost cycle.
- Low refrigerant from a leak, which also reduces heating output.
- Setpoint or mode incorrect, or a schedule switching the unit off.
Why the coast is harder on heat pumps
Muizenberg winters are mild but damp, and damp air deposits frost on the outdoor coil quickly. The unit has to defrost more often, which uses energy and time. A clean coil and a working defrost cycle make that process efficient; a corroded coil covered in salt makes it slow and uneven.
Getting the most from the unit
Run the heat pump steadily rather than in short bursts, keep filters clean, and avoid blocking the outdoor unit with covers, plants or stored goods. If the unit is undersized for the room, it will run continuously on cold mornings and never quite reach the setpoint.